Storage Tank Testing
and Inspections

Certified Storage Tank Inspection and Testing (NDT)
in the El Paso, TX area

Discover why corporations in the El Paso, TX area choose Genesis Environmental Solutions for aboveground and underground storage tank integrity testing and inspections.

Non-Destructive Testing

Non-Destructive Testing Services

Certified Inspectors

API 1631, 653, 510 and STI SP001 Certified Inspectors

Advanced Testing Techniques

Advanced Testing Techniques

Contact us today to request an estimate

Full Service Storage Tank Testing

Looking for professional storage tank inspections and tank integrity testing in the El Paso, TX area? Genesis Environmental Solutions’ personnel have extensive experience, specialty training and state of the art equipment for inspecting any type of tank including fuel, oil, sludge, water and chemical tanks.

Services and Capabilities

ASME, AWS and API NDE Inspections
Vacuum Box Examination (VB)
Magnetic Flux Leakage (MFL/MFE)
Ultrasonic Thickness Testing (UTT)
Visual Testing (VT)
Shell Plate UT, Head UT, and Through Coating UT
Magnetic Particle Testing (MT)
Penetrant Testing (PT)
Dry Film Coating Inspection
Ultrasonic Shear Wave Testing (UTSW)

Certified to do the job right

Our personnel have certifications from both the American Petroleum Institute and Steel Tank Institute in the inspection and operation of these tanks, including:

  • API 653 Aboveground Storage Tank Inspection Certification
  • API 1631 Underground Storage Tank Inspection Certification
  • API 510 Pressure Vessel Inspection Certification
  • API 570 Piping Inspection Certification
  • Steel Tank Institute (STI) SP001 Tank Inspection Certifications

This combination of expertise and nationally recognized certifications allow us to provide services for all types of projects, from a single fuel station tank to field-built erected tank farms.

You can trust Genesis for professional tank testing and environmental services.

  • The facility manager gave great reports about the Genesis employees on their professionalism and hard work. I have listed below an excerpt: 'Very professional. I would definitely recommend them to anyone else.'

    Jason Crum, Co-op Project Engineer, Ergon, Inc.

Industries Served

Just a sample of the industries we work with in the El Paso, TX area.

Water & Wastewater

Bridge & Highway

Petrochemical

Pipelines & Terminals

Food & Beverage

Manufacturing

Power Generation

municipalities

engineering

Recent Projects

A few examples showing the range of projects that our storage tank division has worked on.

YRC
Inspection & Cleaning Client: YRC Worldwide Inc.

Performed tank cleaning and API 653 tank inspections and similar service inspections for YRC Worldwide. Fuel was removed and recycled prior to cleaning and inspection services.

West Plains Energy
Diesel Storage Tank Client: West Plains Energy

Genesis was awarded this diesel storage tank project from West Plains Energy. The project included a API 653 inspection in addition to a coatings and lining application.

KCPL Tank
5.2 Million Gallon Tank Client: Kansas City Power & Light

Performed tank inspection, cleaning, internal tank lining, piping replacement and containment grading for KCP&L. Project included coatings application on transfer pump station piping.

Contact us today to request an estimate

Our Clients

Clients we've done projects for over the years.

Tank Inspection FAQ

Your questions answered about tank inspections in the El Paso, TX area.

Under 40 CFR 112 (SPCC Rule), facilities storing 1,320 gallons or more of oil in ASTs (each container ≥ 55 gal) that have a reasonable expectation of discharge into navigable waters—such as the Rio Grande, which runs along El Paso's international border—must maintain an SPCC Plan. That plan must include documented inspections of tanks, piping, valves, and containment systems to demonstrate ongoing spill prevention and response readiness.

Texas maintains a multi-layered AST regulatory program administered by the Texas Commission on Environmental Quality (TCEQ) Petroleum Storage Tank Program. Under 30 TAC Chapter 334, Subchapter F, petroleum motor-fuel ASTs with a capacity greater than 1,100 gallons must register with TCEQ and submit construction notifications; the rules also establish release reporting, recordkeeping, and general prohibitions, though no state-mandated periodic inspection frequency is set for routine petroleum ASTs under this subchapter. A separate layer, 30 TAC Chapter 338 (the Aboveground Storage Vessel Safety Program, effective August 24, 2023), imposes safety performance standards, mandatory registration by September 1, 2027, and self-certification requirements on large ASVs (≥ 21,000 gallons) at petrochemical plants, petroleum refineries, and bulk storage terminals. For oil-storage facilities subject to the federal SPCC Rule, inspection intervals are governed by the applicable SPCC Plan, with STI SP001 (shop-built tanks) and API 653 (field-erected tanks) commonly used as the underlying inspection standards. Additionally, the City of El Paso has adopted the International Fire Code with local amendments under El Paso City Code Chapter 9.52 (Ordinance HQ 23-345), which requires operational permits and imposes installation and safety standards on flammable and combustible liquid storage, including ASTs.

Genesis Inspection Services helps El Paso-area businesses operating aboveground storage tanks navigate this layered compliance environment. Whether your facility is in El Paso County or the broader West Texas region, our certified API 653 and STI SP001 inspectors provide the thorough documentation you need to demonstrate compliance with EPA SPCC regulations and Texas state requirements under TCEQ's petroleum storage tank program.

API 653 inspections are required for large, field-erected aboveground storage tanks (ASTs) that are constructed to the API 650 standard. In El Paso, these tanks are commonly used by petroleum terminals, manufacturing plants, chemical facilities, and utilities to store fuel, oil, or hazardous liquids. If your tank is over 75,000 gallons, made from welded-steel construction, has a diameter of 30 feet or more, or a height of 50 feet or more, there's a high likelihood it falls under API 653 requirements.
STI SP001 inspections are typically required for shop-fabricated aboveground storage tanks under 75,000 gallons, often found at gas stations, commercial facilities, and industrial properties. If you're storing oil or hazardous substances in El Paso, you may be subject to the EPA's Spill Prevention, Control, and Countermeasure (SPCC) rules for this inspection.
The frequency depends on the tank size, contents, and regulatory classification. In general, API 653 recommends formal external inspections every 5 years and internal inspections every 10-20 years. STI SP001 inspection frequency is determined by their size, category, and risk factors. We can help determine your specific schedule.
Yes. All our inspectors hold API 653 and STI SP001 certifications and are trained in accordance with industry and regulatory standards. We are fully qualified to perform inspections anywhere in Texas, including El Paso.